Aalborg Instruments
Secure Login  English language   German language  
 Search
About Us
History
Mission
Certification
Press Releases
FAQ
Products
Product Overview
Product Configurator
Purchase By SKU
Online Store
Warranty Registration
Resources
Literature / Downloads
Calibration Library
Distributors
Find By Country
O.E.M. Application
Contact Us
Categories
Variable Area Flow Meters »
Thermal Mass Flow Meters »
Thermal Mass Flow Controllers »
Multi-Parameter Mass Flow Controllers »
Paddlewheel Meters
Pumps
Valves »
Accessories »

All Products ...
Information
  • Contact Us
  • ISO9001 Certification
  • Our Mission
  • Shipping & Returns
  • Privacy Policy
  • Conditions of Use
  • About Us
  •  
  • Press Releases
  • FAQ
  • Site Map
  Overview     Configurator     Purchase by SKU     Online Store  
Product Overview »  Paddle Wheel Flowmeters »  PWE paddle-wheel flow meter

PWE paddle-wheel flow meter

PWE paddle-wheel flow meter, Aalborg PWE

Product Summary


PWE paddle-wheel flowmeter for liquid flow measurement.

Design Features

  • Supports up to 23 Engineering Units (including one User Defined)
  • Two programmable Totalizers (main and pilot) indicate total liquid volume
  • Programmable High and low Flow Alarm limits with preset delay interval
  • Programmable High and low Temperature Alarm limits with preset delay interval (optional)
  • Two sets of user programmable optically isolated outputs
  • User selectable (via jumpers) analog 0-5 Vdc or 4-20mA flow and temperature (optional) outputs
  • Flow Pulse output (3.3Vdc CIMOS)
  • Digital Interface (RS-232 or RS-485)
  • Multi-Drop Capability of up to 256 units (RS-485 option)
  • Extensive Self Diagnostic with LCD (optional) indication
  • Local key pad and 2x16 characters LCD display with adjustable back light (optional)
  • Enclosure weather tight to IP65 standards
  • Free AALBORG configuration and calibration software (RS-232/RS-485)
Configure
View Store



  • Description

  • Images

  • Links

  • Files / Manuals

PWE paddle-wheel flow meter

Principles of Operation

Liquid flowing through the unit causes the paddlewheel to spin. As the magnets embedded in the paddle wheel spin past the sensor, electrical pulses are produced in which the frequency is proportional to the flow rate. The number of pulses per desired time interval and the K-factor (number of pulses/Gallon) make it is possible to calculate the flow rate and volume passing through the unit. On board CPU and signal conditioner circuitry perform accurate flow and total computation, digital communication and provide analog 0-5 Vdc or 4-20 mA output signals. Non-volatile memory stores all hardware specific and ser programmable variables, including flow linearization table. The flow rate can be displayed in 23 different volumetric or ass flow engineering units. Flow meter parameters and functions can be programmed locally via key pad and LCD* or remotely via the RS-232/RS-485 interface. PWE flow meters support various functions including: two independently programmable flow totalizers, user programmable low, high or range flow and temperature* alarm, two sets of user programmable optically isolated outputs, self diagnostic alarm, flow pulse output. Optional local 2x16 LCD* readout with adjustable back light provides flow rate, temperature*, total volume reading in currently selected engineering units, diagnostic events indication and feature a password protected access to the process parameters to ensure against tampering or resetting.

SPECIFICATIONS

FLOW MEDIUM Please note that PWE Flow Meters are designed to work only with liquids. Never try to measure flow rates of dry gas.
CALIBRATIONS Performed at standard conditions [14.7 psia (101.4 kPa) and 70°F (21.1°C)] unless otherwise requested or stated.
VISCOSITY Calibrated to 1 cSt (water). Meters with display can be used for fluids up to 50 cSt with field calibration (maximum flow range may be affected).
ENVIRONMENTAL (PER IEC 664) Installation Level II; Pollution Degree II.
FLOW ACCURACY (INCLUDING LINEARITY) ±1% of FS
REPEATABILITY ±0.25% of full scale.
FLUID TEMPERATURE MEASUREMENT RANGE* -10 to 70 °C
TEMPERATURE ACCURACY (INCLUDING LINEARITY)* ±0.5 °C
FLOW RESPONSE TIME approximately 1 seconds (above 10% of full scale flow), approximately 2 seconds (below 10% of full scale flow)
MAXIMUM PRESSURE 10 bar (150 psi)
MAXIMUM PRESSURE DROP 1.4 bar (20 psi) at 132.5 L/min flow. See Table IV for pressure drops associated with various models and flow rates.
FLUID AND AMBIENT TEMPERATURE 14°F to 160°F (-10°C to 70°C)
OUTPUT SIGNALS
 Power consumption:
 Linear 0-5 Vdc (3000 ohms min load impedance)
 Linear 4-20 mA (500 ohms maximum loop resistance)
 Maximum noise 20mV peak to peak (for 0-5 Vdc output)
 Flow Pulse Output: 3.3 Vdc amplitude (3000 ohms min load impedance)
OPTICALLY ISOLATED OUTPUTS UCE @ 40Vdc, ICE @ 150 mA
FLOMETER INPUT POWER 11 to 26 Vdc, 100 mV maximum peak to peak output noise
 Power consumption:
 +12Vdc (150 mA maximum)
 +24Vdc (100 mA maximum)
Circuit board have built-in polarity reversal protection, 300mA resettable fuse provide power input protection.
COMMUNICATIONS PARAMETERS (RS-232/RS-485)
 Baud rate: .................... 9600 baud
 Stop bit: ....................... 1
 Data bits: ...................... 8
 Parity: .......................... None
 Flow Control: ............... None
DISPLAY* Optional local 2x16 characters LCD with adjustable backlight (2 lines of text).
KEY PAD* Optional 4 push button key pad.
CE COMPLIANCE EMC Compliance with 89/336/EEC as amended.
Emission Standard: EN 55011:1991, Group 1, Class A
Immunity Standard: EN 55082-1:1992

(* - optional feature)
PWE paddle-wheel flow meter, Aalborg PWE
  • Paddle Wheel Flowmeters
  • PWM paddle-wheel flow meter
Pdf PWE meter literature
PWE Paddle-wheel flowmeter catalog page(s)

Pdf Digital and Analog Flow Meters Catalog
Full line Digital and Analog Flow Meters, Controllers, Valves and Accessories Catalog

Pdf PWE Digital Paddle Wheel Flow Meter Operating Manual
PWE Operating Manual - TD-08-15-118N, Oct-2022

Pdf Rotameter Catalog
Full line Rotameter and Valves Catalog

Zip PWE Configuration Utility Software
PWE Configuration Utility Software Version 2.0.0.1 (Build 0.0.0.2) Windows XP/Vista/7



Searching...

Advanced Search
Search Terms
Search Help [?]


Limit to Category: [+]
Search by Price Range [+]
Price From:

Price To:
Search by Date Added [+]
Date From:

Date To:
Simple Search
Tel: +1 (845) 770.3000 - Fax: +1 (845) 770.3010
Tel: +1 (800) 866.3837 - Toll Free (US / Canada)
Follow Aalborg on LinkedIn  Follow Aalborg on Facebook  Follow Aalborg on Twitter
Conditions of Use  |  Privacy Policy :: © 2025 COPYRIGHT Aalborg. All Rights Reserved.
AALBORG® is a registered trademark of AALBORG INSTRUMENTS & CONTROLS, INC.