Aalborg Instruments
Secure Login  English language   German language  
 Search
About Us
History
Mission
Certification
Press Releases
FAQ
Products
Product Overview
Product Configurator
Purchase By SKU
Online Store
Warranty Registration
Resources
Literature / Downloads
Calibration Library
Distributors
Find By Country
O.E.M. Application
Contact Us
Categories
Variable Area Flow Meters »
Thermal Mass Flow Meters »
Thermal Mass Flow Controllers »
Multi-Parameter Mass Flow Controllers »
Paddlewheel Meters
Pumps
Valves »
Accessories »

All Products ...
Information
  • Contact Us
  • ISO9001 Certification
  • Our Mission
  • Shipping & Returns
  • Privacy Policy
  • Conditions of Use
  • About Us
  •  
  • Press Releases
  • FAQ
  • Site Map
  Overview     Configurator     Purchase by SKU     Online Store  
Product Overview »  Variable Area Flow Meters (Rotameters) »  model G gas proportioner meters

model G gas proportioner meters

model G gas proportioner meters, G METER model G gas proportioner meters, A meter021 model G gas proportioner meters, Tube adjusted

Product Summary


model G multi gas flow meter for low flow rate gas blending and measurement

Design Features

  • blending of two or three gases with gas proportioners obviates the need for:
    • ordering fixed gas mixtures
    • contamination from reusable gas cylinders
    • potentially inaccurate mixtures by gas suppliers
  • rib-guided or fluted metering tubes facilitate stable/accurate readings
  • magnifier lens in front shield to enhance reading resolution
  • interchangeability of flowtubes and floats
  • OPTIGRAD™ scales minimize parallax and eye fatigue
  • simple means of panel mounting
Configure
View Store



  • Description

  • Images

  • Links

  • Files / Manuals

model G gas proportioner meters

Blending two or three gases in homogeneous infinitely variable concentrations directly at the end use point, this model G gas proportioner is unsurpassed in convenience and economy. Gas proportioners pay for themselves since they eliminate the need for expensive custom blended gas mixtures. They lend flexibility and economy to the utilization of component gas cylinders and “piped-in” supply lines.

Another advantage in laboratory investigations is the freedom to reproducibility increase or decrease concentrations during the course of an experiment.

The flowrates are not affected by downstream pressure variations as long as back pressures do not approach or exceed the input pressure. Input pressures of up to 200 psig (13.8 bars) can be used; however, customers very often find 50 psig (3.45 bars) a convenient setting to work with.

BUILT-IN VALVES
Variable area flow meters (rotameters) are available with built-in needle valves (CV™), high precision metering valves (MFV™) with “non-rising stems”, or with no valves. The higher cost of MFV™ valves is justified whenever high sensitivity control and resolution are desirable particularly in conjunction with metering tubes of very low flowrates.

SPECIFICATIONS [standard component]
STANDARD ACCURACY ±2% FS (mm scales) except 032/042 flow tubes ±5% FS
CALIBRATED ACCURACY ±1% FS
REPEATABILITY ±0.25% FS Typical calibration curves for air at 50 psig/3.5 bars using glass floats are available. Consult with Aalborg on the availability of calibration data for non-hazardous gases and special individual calibrations.
USEFUL FLOW RANGE 10:1 minimum with one float and better than 20:1 with combination of two floats installed in meters
MAXIMUM OPERATING PRESSURE 200 psig (13.8 bars)
MAXIMUM OPERATING TEMPERATURE 250°F (121°C)
MATERIALS OF CONSTRUCTION
FLOW TUBES heavy walled borosilicate glass
FLOATS glass, sapphire, 316 stainless steel, carboloy and tantalum
CHOICE OF MOUNTING FITTINGS IN CONTACT WITH GASES
  • aluminum, black anodized
  • 316 stainless steel
SIDE PANELS aluminum, black anodized
FRONT SHIELD 1/8 inch thick clear polycarbonate
BACK PLATE 1/8 inch thick white acrylics
O-RING and PACKING Buna-n o-rings standard in aluminum models; Viton® o-rings standard in stainless steel models; optional Viton®, PTFE/Kalrez®, EPR
CONNECTIONS 1/8 inch NPT female inlet and outlet connections; optional 1/4 inch FNPT, hose and compression fittings are available
VITON® and KALREZ® are registered trademarks of DuPont Dow Elastomers
model G gas proportioner meters, G METER model G gas proportioner meters, A meter021 model G gas proportioner meters, Tube adjusted
  • Variable Area Flow Meters (Rotameters)
  • model P meter
  • model Px meter
  • model T meter
  • model Tx meter
  • model S meter
  • Variable Area Flow Meter Accessories
  • Calibration Service
  • Rotameter Flow-Tube Calibration Data Library
Pdf G meter literature
model G - Gas Proportioner - Aluminum or 316 Stainless Steel rotameter catalog page(s)

Pdf Technical Information (Rotameter)
  • Valve Flow Capacities
  • Metering Sizing
  • Calculation vs Calibration
  • Table of Standard Flow Capacities
  • Table of Direct Reading Scales
  • Common Equivalents and Conversions


Pdf Rotameter Catalog
Full line Rotameter and Valves Catalog

Pdf Digital and Analog Flow Meters Catalog
Full line Digital and Analog Flow Meters, Controllers, Valves and Accessories Catalog



Searching...

Advanced Search
Search Terms
Search Help [?]


Limit to Category: [+]
Search by Price Range [+]
Price From:

Price To:
Search by Date Added [+]
Date From:

Date To:
Simple Search
Tel: +1 (845) 770.3000 - Fax: +1 (845) 770.3010
Tel: +1 (800) 866.3837 - Toll Free (US / Canada)
Follow Aalborg on LinkedIn  Follow Aalborg on Facebook  Follow Aalborg on Twitter
Conditions of Use  |  Privacy Policy :: © 2025 COPYRIGHT Aalborg. All Rights Reserved.
AALBORG® is a registered trademark of AALBORG INSTRUMENTS & CONTROLS, INC.