Configurator Pages: Find flow tubes

Model T
model T single flow tube PTFE metersmodel T single flow tube PTFE metersmodel T single flow tube PTFE metersmodel T single flow tube PTFE meters » model T single flow tube PTFE meters

model T single tube PTFE/Glass flow meter for low flow rate measurement


Your selection

You must select 2 flow tube(s)

What's this?
Part Number:  T21T1-TA2
I'm looking for
Scale:
What's this?
Metering Fluid:
What's this?
Float Material:
What's this?
Maximum Flow Rate: [std. ml/min]
What's this?
Metering Condition:
What's this?
 
Sort Criteria  Ascending    Descending
 
Flow tubes found
Page 1 of 199
1192 available flow tubes based in your selections
Flowtube: 042-15-GL Scale: Millimeter Scale
Q Min: 0.017 Q Max: 0.188
Float Material: Glass Metering Fluid: Water
Units: std. ml/min Float Density: 2.53 g/ml
Metering Pressure: 14.70 psia Metering Temp: 70.0 °F
Metering Density: 1.00 g/ml Std Density: 1.00 g/ml
Viscosity: 1.0 cp Accuracy: +/-5%FS
Flowtube: 042-15-SA Scale: Millimeter Scale
Q Min: 0.033 Q Max: 0.375
Float Material: Sapphire Metering Fluid: Water
Units: std. ml/min Float Density: 3.98 g/ml
Metering Pressure: 14.70 psia Metering Temp: 70.0 °F
Metering Density: 1.00 g/ml Std Density: 1.00 g/ml
Viscosity: 1.0 cp Accuracy: +/-5%FS
Flowtube: 032-41-GL Scale: Millimeter Scale
Q Min: 0.030 Q Max: 0.500
Float Material: Glass Metering Fluid: Water
Units: std. ml/min Float Density: 2.53 g/ml
Metering Pressure: 14.70 psia Metering Temp: 70.0 °F
Metering Density: 1.000 g/ml Std Density: 1.000 g/ml
Viscosity: 1.00 cp Accuracy: +/-2%FS
Flowtube: 032-41-GL Scale: Millimeter Scale
Q Min: 0.044 Q Max: 0.769
Float Material: Glass Metering Fluid: Butene
Units: std. ml/min Float Density: 2.53 g/ml
Metering Pressure: 147.00 psig Metering Temp: 70.0 °F
Metering Density: 0.6 g/ml Std Density: 0.6 g/ml
Viscosity: Accuracy: +/-10%
Flowtube: 042-15-ST Scale: Millimeter Scale
Q Min: 0.081 Q Max: 0.915
Float Material: S.Steel Metering Fluid: Water
Units: std. ml/min Float Density: 8.04 g/ml
Metering Pressure: 14.70 psia Metering Temp: 70.0 °F
Metering Density: 1.00 g/ml Std Density: 1.00 g/ml
Viscosity: 1.0 cp Accuracy: +/-5%FS
Flowtube: 032-41-SA Scale: Millimeter Scale
Q Min: 0.050 Q Max: 0.990
Float Material: Sapphire Metering Fluid: Water
Units: std. ml/min Float Density: 3.98 g/ml
Metering Pressure: 14.70 psia Metering Temp: 70.0 °F
Metering Density: 1.000 g/ml Std Density: 1.000 g/ml
Viscosity: 1.00 cp Accuracy: +/-2%FS